The choice of the cable diameter connected to the battery is made according to the power of the inverter.

Length (Go + Return) between battery and inverter
  ≤1m ≤2m ≤3m ≤4m ≤6m ≤8m ≤10m ≤12m ≤14m ≤16m
150 W 0.75 1.5 2.5 4 6 6 10 10 16 16
300 W 1.5 4 6 6 10 16 16 25 25 25
600 W 4 6 10 16 25 25 35 35 50 50
1000 W 6 10 16 25 35 50 50 70 95 95
1200 W 6 16 25 25 50 50 70 95 95 120
1500 W 10 16 25 35 50 70 95 95 120 120
1700 W 10 25 35 35 70 70 95 120 150 150
2000 W 10 25 35 50 70 95 120 150 150 -
2500 W 16 35 50 50 95 120 150 - - -
3000 W 16 35 50 70 95 150 - - - -
4000 W 25 50 70 95 150 - - - - -
5000 W 35 50 95 120 - - - - - -
6000 W 35 70 95 150 - - - - - -
Length (Go + Return) between battery and inverter
  ≤1m ≤2m ≤3m ≤4m ≤6m ≤8m ≤10m ≤12m ≤14m ≤16m
150 W 0.5 0.5 0.75 0.75 1.5 1.5 2.5 2.5 4 4
300 W 0.5 1 1.5 1.5 2.5 4 4 6 6 6
600 W 1 1.5 2.5 4 6 6 10 10 10 16
1000 W 1.5 2.5 4 6 10 10 16 16 25 25
1200 W 1.5 4 4 6 10 16 16 25 25 25
1500 W 2.5 4 6 10 16 16 25 25 25 35
1700 W 2.5 6 10 10 16 25 25 35 35 35
2000 W 2.5 6 10 10 16 25 25 35 35 50
2500 W 4 6 10 16 25 35 35 50 50 50
3000 W 4 10 16 16 25 35 50 50 50 70
4000 W 6 10 16 25 35 50 50 70 70 95
5000 W 6 16 25 25 50 50 70 95 95 120
6000 W 10 16 25 35 50 70 95 95 120 120
Section mm² 0.75 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150
Diameter mm 1 1.4 1.8 2.2 2.8 3.6 4.5 5.6 6.7 8 9.5 11 12.4 14